Online inquiry
Mon - Fri : 09.00 AM - 09.00 PM
13161687800
All Aluminum Conductor (AAC) Price:¥ Id:ACC

High Quality Overhead Line All Aluminum conductor Application AAC conductor is also known as aluminum stranded conductor, which are used in urban areas where spans are usually short but high conductivity is required, and are in common use on overhead lines for in low, medium and high voltage. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Although aluminium-to-copper connections can be made, it is better to use aluminium conductors for service connections, as various forms of covered cable are available for this purpose

Online inquiry
Detailed content Specification parameter Product packaging

All Aluminum Alloy Conductors structure

Construction

Concentric lay stranded Aluminium Conductor is manufactured from electrolytic ally refined aluminium with a minimum purity of 99.7%. and made up of one or more strands of hard drawn 1350 aluminum.

Characteristics

Electrical Properties

  • Density at 20℃: 2.703 kg/dm3

  • Temperature Coefficient at 20°C: 0.00403 (°C)

  • Resistivity at 20°C: 0.028264Ω•mm2/m

  • Coefficient of linear expansion: 23 x10-6 (°C)

Service Conditions

  • Seismic Acceleration: 0.12 – 0.05g

  • Ambient Temperature: -5°C – 50°C

  • Wind Pressure: 80 – 130kg/m2

  • Isokeraunic Level: 10 – 18

  • Relative Humidity: 5 – 100%

Specifications

All Aluminum Conductors (AAC) IEC 61089 Standard

CodeNominal cross-sectional area
mm2
Number of strandsDiameterApproximate weight of cable
kg/km
Nominal
Breaking Load
kN
Maximum DC Resistance at 20℃
Ω/km
Single wire
mm
Conductor
mm
101071.354.0527.41.952.8633
161671.715.1243.83.041.7896
252572.136.4068.44.501.1453
404072.708.09109.46.800.7158
636373.3910.2172.310.390.4545
100100192.5912.9274.817.000.2877
125125192.8914.5343.621.250.2302
160160193.2716.4439.826.400.1798
200200193.6618.3549.732.000.1439
250250194.0920.5687.140.000.1151
315315373.2923.0867.951.970.0916
400400373.7126.01102.064.000.0721
450450373.9427.51239.872.000.0641
600600374.1529.01377.680.000.0577
560560374.3930.71542.989.600.0515
630630613.6332.61738.3100.800.0458
710710613.8534.61959.1113.600.0407
800800614.0936.82207.4128.000.0361
900900614.3339.02483.3144.000.0321
10001000614.5741.12759.2160.000.0289
11201120913.9643.53093.5179.200.0258
12501250914.1846.03452.6200.000.0231
14001400914.4348.73866.9224.000.0207
15001500914.5850.44143.1240.000.0193

All Aluminum Conductors (AAC) DIN 48201-5 Standard

Nominal cross-sectional areaNo./Diameter of single wireApproximate
overall diameter of cable
mm
Approximate weight of cable
kg/km
Nominal
Breaking Load
dN
Maximum DC
Resistance at 20℃
Ω/km
Current
Rating
A
Nominal
mm2
Actual
mm2
1615.897/1.705.1442901.801883
2524.257/2.106.3674251.1808108
3534.367/2.507.5945850.8332134
5049.487/3.0091358100.5786168
5048.3619/1.8091338600.595166
7065.8219/2.1010.518111500.4371200
9593.2719/2.5012.525615950.3084248
12011719/2.801432219100.2459285
150147.137/2.2515.240625700.196328
185181.637/2.5017.550131050.1587373
240242.5461/2.2520.267040150.1191445
300299.4361/2.5022.582748500.0965506
400400.1461/2.8926110561900.07221602
500499.8361/3.2329.1138176000.05781688
625626.291/2.9632.6173396900.04625786
800802.191/3.3536.82219120550.03611907
1000999.7191/3.7441.12766148450.028971026

All Aluminum Conductors (AAC) ASTM B231 Standard

CodeNominal cross-sectional areaNo./Diameter of single wireApproximate
overall diameter of cable
mm
Approximate weight of cable
kg/km
Nominal
Breaking Load
dN
Maximum DC
Resistance at 20℃
Ω/km
AWG or MCMmm2
Peachbell613.297/1.5544.67372492.1692
Pose421.167/1.9615.89583961.3624
Iris233.617/2.4747.42935970.8577
Pansy142.397/2.7768.331177320.6801
Poppy1/053.487/3.1199.361478730.5390
Aster2/067.427/3.50310.5118611000.4276
Phlox3/085.037/3.93211.8023413470.3390
Oxlip4/0107.237/4.41713.2629616980.2688
Valerian250126.7119/2.91314.5734920620.2275
Sneezewort250126.717/4.8014.434920070.2275
Laurel266.8135.1619/3.0115.0537322000.2133
Daisy266.8135.167/4.9614.937321410.2133
Peony300152.019/3.19315.9741924030.1896
Tulip336.4170.4519/3.38116.9147026950.1691
Daffodil350177.3519/3.44717.2448928040.1625
Canna397.5201.4219/3.67318.3655531840.1431
Goldentuft45022819/3.90919.5562934990.1264
Syringa477241.6837/2.88220.1966638490.1193
Cosmos477241.6819/4.02320.1266637080.1193
Hyacinth500253.3537/2.95120.6569840350.1138
Zinnia500253.3519/4.1220.669838880.1138
Dahlia556.528219/4.34621.7377743270.1022
Mlstletoe556.528237/3.11421.7977743620.1022
Meadowsweet60030437/3.23322.6383847030.0948
Orchid636322.2537/3.3323.3183849850.0894
Heuchera650329.437/3.3723.59907.451.70.0871
Flag700354.7161/2.7224.4897851460.0813
Verbena700354.7137/3.49324.4597854870.0813
Nasturtium715.5362.5861/2.7524.76100058740.0795
Violet715.5362.5837/3.53324.74100056090.0795
Cattail75038061/2.81725.35104859850.0759
Petunia75038037/3.61725.32104858750.0759
Lilac795402.8461/2.9026.06111163450.0715
Artubus795402.8437/3.72426.05111162320.0715
Snapdragon900456.0661/3.08627.78125769780.0632
Cockscomb900456.0637/3.96227.73125768480.0632
Goldenrod954483.4261/3.17728.6133378960.0596
Magnolia954483.4237/4.07928.55133372580.0596
Camelia1000506.7161/3.25129.36139777530.0569
Hawkweed1000506.7137/4.17629.23139776080.0569
Larkspur1033.5523.6861/3.30729.76144480120.0550
Bluebell1033.5523.6837/4.24429.72144478630.0550
Marigold1113563.9361/3.43230.89155586280.0511
Hawthorn1192.5604.2661/3.55131.05166692450.0477
Narcissus1272644.5161/3.66833.02177798610.0477
Colunbine1351.5684.8461/3.7834.011888104780.0421
Canation1431725.1061/3.8935.031999107680.0398
Gladiolus1510.5765.3561/4.0035.092110113650.0376
Coreopsis1590805.6861/4.09936.512221119640.0358
Jessamine1750886.7161/4.30238.732445131680.0325
Cowslip20001013.4291/3.7641.402791153000.0285
Lupine25001266.6791/4.2146.303524187000.0230
Trillum30001520.13127/3.9050.754232225000.0192
Blue Bonnet35001773.50127/4.2154.804985262000.0166

All Aluminum Conductors (AAC) BS 215 part1 Standard

CodeNominal cross-sectional areaNo./Diameter of single wireApproximate
overall diameter of cable
mm
Approximate weight of cable
kg/km
Nominal
Breaking Load
dN
Maximum DC Resistance at 20℃
Ω/km
Nominal
mm2
Actual
mm2
Midge2223.337/2.066.18643991.227
Aphis2526.43/3.357.2734111.081
Gnat2526.87/2.216.6734591.066
Weevil3031.63/3.667.9864860.9082
Mosquito35377/2.597.81016030.7762
Ladybird4042.87/2.798.41176870.6689
Ant5052.837/3.109.31458280.5419
Fly6063.557/3.4010.21749900.4505
Bluebottle7073.77/3.661120211340.3881
Earwig7578.57/3.7811.421511940.3644
Grasshopper8084.17/3.9111.723012780.3406
Clegg9095.67/4.1712.526214530.2994
Wasp1001067/4.3913.1729016000.2702
Beetle10010619/2.6713.429317420.2704
Bee1251327/4.9014.736119940.2169
Cricket150157.97/5.3616.143223850.1818
Hornet150157.619/3.2516.2543425700.1825
Caterpillar17518619/3.5317.751228630.1547
Chafer200213.219/3.7818.958732400.1349
Spider225236.919/3.992065236010.1211
Cockroach250265.719/4.2221.173140400.1083
Butterfly300322.719/4.6523.2588848750.0892
Moth350373.219/5.0025102756370.0771
Drone350373.337/3.5825.1102957450.0774
Locust400428.519/5.3626.8117964730.0671
Centipede400415.237/3.7826.46114563100.0694
Maybug450486.937/4.0928.6134274010.0593
Scorpion500529.537/4.2729.9146079980.0544
Cicada600628.637/4.6532.6173394950.0459
Tarantula750794.637/5.2336.62191120100.0363

All Aluminum Conductors (AAC) BS EN 50182 Standard

CodeNominal cross-sectional areaNo./Diameter of single wireApproximate
overall diameter of cable
mm
Approximate weight of cable
kg/km
Nominal
Breaking Load
dN
Maximum DC
Resistance at 20℃
Ω/km
Nominal
mm2
Actual
mm2
Aphis2526.403/3.357.2734111.081
Gnat2526.87/2.216.6734591.066
Weevil3031.63/3.337.9864860.9082
Mosquito35370.7/2.597.91016030.7762
Ladybird4042.87/2.798.41176870.6689
Bluebottle7073.77/3.6611.020211340.3881
Earwig7578.57/3.7811.421511940.3644
Grasshopper8084.17/3.9111.723012780.3406
Clegg9095.67/4.1712.526214530.2994
Beetle100106.019/2.6713.429317420.2704
Bee125132.07/4.9014.736119940.2169
Cricket150157.97/5.3616.143223850.1818
Caterpillar17518619/3.5317.751228630.1547
Spider225236.919/3.9920.065236010.1211
Moth350373.219/5.0025.0102756370.07711
Drone350373.337/3.5825.1102957450.07741
Locust400428.519/5.3626.8117964730.06710
Maybug450486.937/4.0928.6134274010.05931
Scorpion500529.537/4.2729.9146079980.5441
Cicada600628.637/4.6532.6173394950.04588
Tarantula750794.637/5.2336.62191120100.03627

All Aluminum Conductors (AAC) GB/T1179-2008 Standard

Nominal cross-sectional areaNo./Diameter of single wireApproximate
overall diameter of cable
mm
Approximate weight of cable
kg/km
Nominal
Breaking Load
dN
Maximum DC
Resistance at 20℃
Ω/km
Nominal
mm2
Actual
mm2
1615.897/1.705.143.528401.802
2525.417/2.156.4569.643551.127
3534.367/2.507.594.157600.8332
5049.487/3.009135.579300.5786
7071.257/3.6010.8195.1109500.4018
9595.147/4.1612.48260.5144500.3009
120121.2119/2.8514.25333.5194200.2373
150148.0719/3.1515.75407.4233100.1943
185182.819/3.5017.5503284400.1574
210209. 8519/3.7518.75577.4322600.1371
240238.7619/4.0020656.9362600.1205
300297.5737/3.2022.4820.4468500.0969
400397.8337/3.7025.91097611500.0725
500502.937/4.1629.121387763700.0573
630631.361/3.6332.671744919400.0458
800805.3661/4.1036.922251159000.0359