Online inquiry
Mon - Fri : 09.00 AM - 09.00 PM
13161687800
All Aluminum Alloy Conductors (AAAC) Price:¥ Id:AAAC

Overhead Transmission AAAC Bare Conductors Application AAAC is mainly used as bare overhead transmission cable and as primary and secondary distribution cable. It is also suitable for laying across basins, rivers and valleys where special geographical features exist.

Online inquiry
Detailed content Specification parameter Product packaging

Construction

AAAC cable consists of aluminum alloy wires. The aluminum alloy wires are concentrically stranded.

This section deals with heat-treatable magnesium silicon type aluminium alloys to the applicable International Standard, the electrical and mechanical properties of which all fall within the values suggested by relevant standard.

Conductors to all other recognized specifications can also be supplied. The alloys referred to have higher strength but lower conductivity than pure aluminium.

Being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional ACSR; Having lower breaking loads than the later, their use becomes particularly favorable when ice and wind loadings are low.

Characteristics

Electrical Properties

  • Density at 20℃: 2.703 kg/dm3

  • Temperature Coefficient at 20°C: 0.00360 (°C)

  • Resistivity at 20°C: 0.03260Ω•mm2/m

  • Coefficient of linear expansion: 23 x10-6 (°C)

Service Conditions

  • Seismic Acceleration: 0.12 – 0.05g

  • Ambient Temperature: -5°C – 50°C

  • Wind Pressure: 80 – 130kg/m2

  • Isokeraunic Level: 10 – 18

  • Relative Humidity: 5 – 100%

Specifications

All Aluminium Alloy Conductors AAAC to IEC 61089 Standard

Nominal cross-sectional area
mm2
Actual cross-sectional area
mm2
Number of strandsDiameterApproximate weight of cable
kg/km
Nominal
Breaking Load
kN
Maximum DC
Resistance at 20℃
Ω/km
Single wire
mm
Conductor
mm
1618.671.845.5250.86.041.7896
2529.072.306.9079.59.441.1453
4046.572.918.72127.115.100.7158
6373.273.6510.9200.223.060.4545
100116192.7914.0319.337.760.2877
125145193.1215.6399.247.200.2302
160186193.5317.6511.058.560.1798
200232193.9519.7638.773.200.1439
250290194.4122.1798.491.500.1151
315366373.5524.81008.4115.290.0913
400465374.0028.01280.5146.400.0721
450523374.2429.71440.5164.700.0641
500581374.4731.31600.6183.000.0577
560651613.6933.21795.3204.960.0516
630732613.9135.22019.8230.580.0458
710825614.1537.32276.2259.860.0407
800930614.4039.62564.8292.800.0361
9001046913.8342.12888.3329.400.0321
10001162914.0344.43209.3366.000.0289
11201301914.2746.93594.4409.920.0258

All Aluminium Alloy Conductors (AAAC) to DIN 48201-6 Standard

Nominal cross-sectional area
mm2
Actual cross-sectional area
mm2
Number of strandsDiameterApproximate weight of cable
kg/km
Nominal
Breaking Load
kN
Maximum DC
Resistance at 20℃
Ω/km
Single wire
mm
Conductor
mm
1615.8971.705.1434442.0910
2524.2572.106.3666771.3703
3534.3672.507.5949600.9669
5049.4873.009.013513820.6714
5048.35191.809.013313500.6905
7065.81192.1010.518118380.5073
9593.27192.5012.525626050.3579
120116.99192.8014.032232680.2854
150147.11372.2515.840641090.2274
185181.62372.5017.550050730.1842
240242.54612.2520.367067740.1383
300299.43612.5022.582783630.1120
400400.14612.8926.01104111760.0838
500499.63613.2329.11379139600.06709
625626.20912.9632.61732174900.0540
800802.09913.3536.92218224020.0418
1000999.71913.7441.12767279220.0335

All Aluminium Alloy Conductors(AAAC) to ASTM B 399 Standard

Conductor sizeNo./Diameter of single wireApproximate
overall diameter of cable
mm
Approximate weight of cable
kg/km
Nominal
Breaking Load
kN
Maximum DC
Resistance at 20℃
Ω/km
AWG or MCMmm2
613.37/1.554.6736.894.222.5199
421.147/1.965.8957.896.711.586
233.657/2.477.4292.1410.690.9987
1/053.497/3.129.35146.516.980.6259
2/067.457/3.5010.52184.720.480.4974
3/0857/3.9311.79232.725.880.3945
4/0107.27/4.4213.26293.732.670.3119
250126.719/2.9114.58346.938.970.2651
300152.119/3.1915.89418.646.770.2206
350177.319/3.4617.25485.552.260.1886
400202.719/3.6918.44555.159.760.1649
45022819/3.9119.56624.467.250.1468
500253.419/4.1220.6693.674.650.1322
550278.737/3.1021.67762.983.840.12
60030437/3.2322.6383291.430.1105
650329.437/3.3723.57909.899.030.1015
700354.537/3.4924.46910.6101.930.09464
750380.237/3.6225.321041109.920.08796
800405.437/3.7326.141109116.910.08285
900456.337/3.9627.741249131.910.07351
1000506.737/4.1829.241388145.890.06597
1250633.361/3.6332.671733179.870.05306
150076061/3.9835.822081216.840.04414
1750886.761/4.3038.72429252.820.03781

All Aluminium Alloy Conductors(AAAC) to ASTM B 399 Standard

CodeConductor sizeNo./Diameter of single wireApproximate
overall diameter of cable
mm
Approximate weight of cable
kg/km
Nominal
Breaking Load
kN
Maximum DC
Resistance at 20℃
Ω/km
AWG or MCMmm2
Akron30.5815.487/1.685.0442.684.922.1556
Alton48.69(4)24.677/2.126.3567.567.831.3557
Amas77.47(2)39.267/2.678.02107.512.50.8547
Azusa123.3(1/0)62.467/3.3710.1117119.790.5365
Anahelm155.4(2/0)78.757/3.7811.35215.1623.980.4264
Amherst195.7(3/0)99.27/4.2512.75271.530.170.3373
Altiance246.9(4/0)125.17/4.7714.3342.638.070.2678
Butte312.8158.519/3.2616.3143448.760.2112
Canton394.519919/3.6618.31547.458.960.1676
Calro465.4235.819/3.9819.89645.769.550.1431
Darien559.5283.519/4.3621.79776.383.550.1181
Elgin652.4330.619/4.7123.55970.697.430.1012
Flint740.8375.437/3.5925.151028107.930.08944
Greeley927.2469.837/4.0228.141287135.910.07133

All Aluminium Alloy Conductors (AAAC) to BS 3242 and BS EN 50182 Standard

CodeConductor sizeNo./Diameter of single wireApproximate
overall diameter of cable
mm
Approximate weight of cable
kg/km
Nominal
Breaking Load
kgf
Maximum DC Resistance at 20℃
Ω/km
AWG or MCMmm2
Box1518.827/1.855.55515371.7495
Acacia2023.797/2.086.24656801.384
Almond2530.17/2.347.02828611.0934
Cedar3035.477/2.547.629710140.9281
Deodar3542.187/2.778.3111512050.7804
Fir4047.847/2.958.8513113670.688
Hazel5059.877/3.309.916417110.55498
Pine6071.657/3.6110.8319620480.4594
 Holly7084.057/3.9111.7323024020.3917
Willow7589.737/4.0412.1224525650.3669
8096.527/4.1912.5726427580.3441
901087/4.4413.3229831120.3023
Oak100118.97/4.6513.9532533980.2769
 –100118.719/2.8214.132633930.2787
Mulberry125150.919/3.1815.941543120.2192
Ash150180.719/3.4817.449751640.1831
Elm17521119/3.7618.858060300.1568
Poplar200239.437/2.8720.0965988410.1385
225270.337/3.0521.3574477240.1227
Sycamore250303.237/3.2222.5483588640.1093
Upas300362.137/3.5324.71997103500.09156
Walnut350421.837/3.8126.671162120530.0786
Yew40047937/4.0628.421319136850.06921
Tuatara425498.137/4.1428.981372142330.06656
Rubus500586.961/3.5031.51620167710.05662
Sorbus650659.461/3.7133.391822198500.0505
Araucaria700821.161/4.1437.262266234500.04047
Redwood950996.261/4.56412753299880.0334

All Aluminium Alloy Conductors (AAAC) to BS EN

Code
ASTER
Actual cross-sectional area
mm2
Number of strandsNominal DiameterApproximate weight of cable
kg/km
NominalBreaking Load
kN
Maximum DC Resistance at 20℃
Ω/km
Single wire
mm
Conductor
mm
2222726607.151.4989
34.434.472.57.593.811.170.9593
54.654.673.159.45148.917.730.6042
75.575.5192.2511.3207.424.550.4388
117117192.814321.238.020.2833
148148.1193.1515.8406.548.120.2239
181.6181.6372.517.5500.359.030.1831
228227.8372.819.6627.674.040.146
288288.3373.1522.1794.393.710.1154
366366.2373.5524.91008.9115.360.0908
570570.2613.4531.11576185.330.0585
851850.7913.45382360.7276.470.0394
11441143.5914443173.4360.220.0293
16001595.91274524427.5502.720.021

50183(France) Standard